Skip to content

Industrial software and IIoT

Get the data out of your machines

We connect machines, PLCs and sensors to the systems that need their data. We build protocol gateways between OPC UA, Modbus, Profinet, IO-Link or RS485 and modern transports such as MQTT and gRPC, plus the operator screens that go with them. Every project starts from the real signal list.

We reply within 48 hours on working days (GMT+3).

Who it is for

  • Machine builders and OEMs whose equipment cannot share data
  • Automation integrators adding a data layer to existing lines
  • Plant engineering teams that need one view across machines

Problems we hear

  • “Our PLC data stays on the machine.”
  • “The operator screen cannot show what the line needs.”
  • “Wireless sensors drop data or lock us into one vendor.”
  • “We want events and results in the cloud, not raw streams.”

What you get

  • Connectivity assessment: signal inventory, protocols, rates and constraints
  • Protocol gateway with buffering for network drops
  • Data routing over MQTT, WebSocket or gRPC
  • Touchscreen or industrial PC interface for operators
  • Integration of 2D and 3D cameras, ToF, stereo and laser profile sensors
  • Logs, alerts and a signal map for maintenance

Ways to work together

Connectivity assessment

Fixed scope. Every signal is listed before anyone writes code.

Gateway build

Built on a milestone plan and tested against the real PLC.

Retrofit and support

Installed in a planned maintenance window, with optional support after go-live.

How we measure

  • Tested against the actual PLC or sensor, not only against a simulator.
  • Cycle time, packet loss and reconnect behavior recorded and reported.

Technologies

  • OPC UA
  • Modbus
  • Profinet
  • IO-Link
  • RS485 and RS232
  • MQTT
  • gRPC
  • WebSocket
  • BLE
  • WiFi
  • LoRaWAN
  • ZigBee
  • Siemens
  • SICK
  • Leuze
  • Advantech
Can you connect a legacy PLC without changing its program?

Often, yes. It depends on the PLC's network options and protocols, and the assessment confirms it before you commit.

Do you send raw data to the cloud?

Only when the use case needs it. Usually we send events and summaries, and keep raw data on site.

Which protocols do you work with?

OPC UA, Modbus, Profinet, IO-Link, RS485 and RS232 on the machine side; MQTT, gRPC and WebSocket upstream; BLE, WiFi, LoRaWAN and ZigBee for wireless sensors.

Have a device, machine or model that must work on real hardware?

Send the goal, the target hardware and the deadline. We reply within 48 hours on working days. If we are not the right team, we will say so.

Need a senior engineer inside your team? Contract, fractional and advisory work, for three months or longer.

Hire an engineer